TMS RF for Windows
Torque measurement software for a Windows PC. An RF 2.4G USB receiver brings in torque and angle data from ZIPPTORK wireless sensors; TMS RF shows readings and curves in real time, judges OK / NOK against your target and tolerance, and stores every result in a database on the computer.
- 6 work modes
- Modbus TCP / RTU & Open Protocol
- Excel / CSV export
- 16 interface languages

How TMS RF works
TMS RF turns the wireless data of ZIPPTORK torque sensors into judged, stored and shareable tightening results.
Connect
Plug the RF 2.4G receiver into a USB port of the computer. It appears as a COM port and receives data from the wireless sensors.
Pair
Pair each torque sensor to an RF channel in System Settings › Sensor Pairing. Every work mode needs pairing first.
Measure
Choose a work mode, set the target torque and tolerance, and tighten. Work starts automatically when you open the work screen.
Review & share
Every result is saved as a record you can query, export to Excel or CSV, synchronise, or provide to a PLC.
Safety: TMS RF is a measurement and recording tool. It does not control or cut off the power of external machinery, so follow the safety rules of the tool manufacturer and your factory when applying torque.
Five tightening modes, one judgement you can trust
The “Rotary Sensor” group of the navigation menu holds five tightening and measurement modes; the “Tool Capability” group adds the capability test. Each mode judges OK or NOK on the quantity that matters for the job.
Torque Wrench
Judges OK or NOK by the peak torque of each torque application, for tightening checks and spot checks with manual torque wrenches.
An application starts when the torque rises above 0 and ends when you release the wrench and the torque returns to 0. There is no Start or Stop button: work starts automatically when you open the work screen and stops when you leave it.
- Large OK / NOK result panel with a range bar for lower limit, target and upper limit
- Torque chart of the last tightening, and OK / NOK / total statistics
- Station and part number recorded with every result
Torque & Angle
For tightening that first reaches a seating torque and then turns to a specified angle. Each application records both the peak torque and the final angle.
OK or NOK is judged according to the control mode and shown after the data has been saved; until then the judgement stays “Pending”.
- The seating torque sets the starting point of angle counting
- Target angle from 1 to 360 degrees
- Needs a sensor that can report angle
Torque Inspection
Measures the torque at the moment the joint has turned a specified angle after the torque reaches a start value, and judges OK or NOK by that torque, called the angle torque.
One start value, “Target Torque (Angle Start)”, is both the starting point of the angle and the centre value for judgement.
- Suited to torque measurement that is started by angle
- Needs a sensor that can report angle
Power Tool
Measures the peak torque of power tools. Choose the tool type that matches your tool: Pulse for hydraulic and pneumatic pulse wrenches, Impact for hammer-type impact wrenches and Clutch for shut-off screwdrivers and wrenches.
The types differ in which torque data the sensor reports and in when one tightening is considered finished, so selecting the correct type matters.
- Pulse and impact tightenings end after two consecutive zero readings
- A clutch tightening ends at the first return to zero
- Pulse count shown on the work screen for pulse and impact tools
Run several steps in the right order
A batch combines several steps – the modes can be mixed – into a workflow the operator completes in order. Only OK results are counted.
One workpiece, several bolts
Each batch has a system-assigned ID (Pset 001 to 999), a batch number, a batch name and an action after completion. Each step has its own work mode, torque sensor, target values, tolerance and batch count – how many OK results the step needs.
A NOK result is still saved, but the step does not advance until you get an OK. When every step is complete the batch either restarts for the next round or stops and returns to the settings screen.
- Step types: Torque Wrench, Torque & Angle, Power Tool and Torque Inspection
- Batches belong to groups, for example a production line or vehicle model, with optional categories for classification and queries
- Open Protocol results are sent from this mode

Check that a tightening tool is stable
“Tool Inspection” evaluates whether an impact, pulse, torque-wrench or clutch tool is repeatable. Set the upper and lower specification limits and tighten repeatedly.
For every captured sample TMS RF judges OK or NOK (a value between the lower and upper specification limit, limits included, is OK), calculates the mean, standard deviation and capability indices, and shows Pass, Marginal or Fail against the acceptance thresholds you set. Each capture is saved as a capability test record.

Torque sensor mode
The peak torque measured by the torque sensor each time the tool tightens – the repeatability of the tool itself (machine capability).
| Index | Meaning |
|---|---|
| M, S | Mean and sample standard deviation of the samples on the page. |
| Cp, Cpk | Potential process capability and process capability index, from the latest 20 samples of the same round. Cpk is shown on screen; Cp is saved in the records. |
| Cm, Cmk | Potential machine capability and machine capability index, from the latest N samples of the same round (N = target sample count). Cmk is shown on screen; Cm is saved in the records. |
| CMU, CML, in-spec % | Upper and lower machine capability values (residual-torque modes) and the percentage of OK samples. |
Every result, traceable
TMS RF keeps records separately for each work mode – Torque Wrench, Power Tool, Torque & Angle, Torque Inspection, Batch Jobs and the capability tests – and every record can be traced to its operator.
Query, inspect and export
On the Records & export page you can view the records of all work modes at once, filter by work mode, date range, station, part number and result, sort the list, and export the query result to Excel or CSV.
Open a record to see its torque chart or torque / angle curve, the work parameters and the sensor information.
- Detail pages with the torque chart or torque / angle curve and the raw samples
- Querying, exporting and deleting depend on the account's permissions
- Capability records are kept as list and detail without a curve
Everything around the measurement
Units, pairing, calibration factors and signalling are set once on the computer and shared by every work mode.

Units and language
Torque unit (kgf·cm, kgf·m, N·m, ozf·in, lbf·in, lbf·ft), force unit (kN, N, lbf, kgf) and 16 interface languages. Changes apply as soon as you select them.

Sensors and RF pairing
Connect the RF 2.4G receiver, pair torque sensors to an RF channel and manage the saved sensors.

Torque factor
Correct the difference between the sensor reading and the actual torque with a reference instrument: Torque Factor = Measured Torque ÷ Displayed Torque.

Torque multiplier
For a sensor on the input side of a torque multiplier: set the gear ratio and torque ratio of each stage. Output torque = sensor torque × total torque ratio.
Hand results to your PLC, MES or database
TMS RF provides measurement results over industrial protocols and interfaces.

Modbus TCP
TMS RF is the server (slave): it opens a TCP port on the computer and a PLC, SCADA system or PC program (the master) connects to read results or write commands.
Network security: Modbus TCP and Open Protocol have no encryption or authentication. Use them on a controlled factory local area network only.
Read-only API and database sync
The read-only API lets programs on the computer or on a trusted production network read the torque and judgement of the current sensor over HTTP. It uses no user name or password, so keep it bound to this computer unless other computers need to read the data.
Database sync pushes completed measurement records through an HTTPS gateway to a MySQL or MS SQL database. TMS RF does not connect to the database directly.
- Choose the sync target on the Sync Settings page
- Changing sync settings needs the “Edit · Server and Sync Settings” permission, by default administrators only
The right access for each role
Every account uses one of three permission templates, shown on screen as Admin, Supervisor and User. An administrator can also switch individual functions on or off for each user.
| Template | Intended for | Default access |
|---|---|---|
| Admin | System administrators | All functions, including managing users, server and sync settings. |
| Supervisor | Engineers, QC staff, shift leaders | Adjust work parameters, pair sensors, calibrate, change file and communication settings; can view the user list but cannot edit users or server and sync settings. |
| User | Shop-floor operators | Run work, view work and system settings, view and export records, run capability tests; cannot change work parameters, pairing or calibration. |
First login: change the password of the default administrator account admin immediately.
Requirements and setup
TMS RF is a 64-bit Windows desktop application. A standard user account is enough: it installs into the current user's folder and needs no administrator rights.
| Item | Requirement |
|---|---|
| Operating system | Windows 10 or Windows 11, 64-bit. 32-bit Windows is not supported. |
| Runtime | Microsoft Edge WebView2 Runtime. Windows 11 usually includes it; the standard installer downloads it when it is missing, so the computer needs a network connection for that step. |
| Hardware | RF 2.4G USB receiver and ZIPPTORK wireless torque sensors; a USB port for an indicator light or a USB to RS-485 converter is optional. |
| Disk space | About 19 MB for the program; keep at least 1 GB free for work records. |
| Recommended | Intel Core i3 / AMD Ryzen 3 or better, 8 GB memory, 1920×1080 display (1366×768 minimum). |
Windows security warning: the TMS RF files have no digital signature, so Windows may show “Unknown Publisher” or a Microsoft Defender SmartScreen message on first run. Confirm that the file comes from ZIPP GROUP – compare its SHA-256 with the value on the download page – and then run it.
Data location: TMS RF stores its database for the current Windows user in %APPDATA%\com.tms.zipptork, wherever the program is installed. Always back up your data before you upgrade, uninstall, or choose “Delete the application data”; deleted data cannot be recovered. When a version is already installed, the setup recommends uninstalling it first.


No network on the production computer? The manual also describes an offline installer that includes WebView2. Ask ZIPP GROUP for it if the standard installer cannot download the runtime.
Frequently asked questions
What do I need to run TMS RF on Windows?
Windows 10 or Windows 11 (64-bit), the Microsoft Edge WebView2 Runtime, an RF 2.4G USB receiver and ZIPPTORK wireless torque sensors. The program needs about 19 MB; keep at least 1 GB free for records.
Does TMS RF control my tightening tool?
No. TMS RF is a measurement and recording tool; it does not control or cut off the power of external machinery.
Can TMS RF exchange data with a PLC or MES?
Yes. TMS RF is the slave for Modbus TCP and Modbus RTU and acts as a tightening controller for Open Protocol. A read-only HTTP API and database sync to MySQL or MS SQL through an HTTPS gateway are also available.
Where is my data stored?
In a database in the current Windows user's application data folder, regardless of where the program is installed. Back it up before upgrading or uninstalling.
Which languages are supported?
The interface supports 16 languages and the operation manual is available in the same 16 languages.
Get TMS RF 1.7.10 for Windows
Download the installer and the operation manual from the software download page. The manual covers installation, every screen, field and button, with examples.




























